EXPLORIS EcoPlus®

Sustainable safety and cost-effectiveness

With its unique flow technology, the energy-efficient EcoPlus® fume cupboard reduces the air flow rate while meeting all safety requirements. The allows operating cost savings up to 30% relative to a comparable standard model.

Bench type fume cupboards are available in EcoPlus® variants and can be retrofitted afterwards

EXPLORIS EcoPlus®

Sustainable safety and cost-effectiveness

With its unique flow technology, the energy-efficient EcoPlus® fume cupboard reduces the air flow rate while meeting all safety requirements. The allows operating cost savings up to 30% relative to a comparable standard model.

Bench type fume cupboards are available in EcoPlus® variants and can be retrofitted afterwards

Safety through flow-optimised geometry without complicated auxiliary air flow technology
Operation with exemplary low 250 m³/h per linear metre of fume cupboard width
Bench type fume cupboards are available in EcoPlus® variants and can be retrofitted afterwards
Reduces the operating costs of the fume cupboard by up to 30 percent depending on the room conditions
Certified according to DIN EN 14175 Part 2 and Part 3
Durability and environmentally friendly disposal thanks to the material steel

Potential savings

Per fume cupboard (1.500 mm) after an operating time of…

Conventional fume cupboard

1 hour

600 m³ / 0,48 €

1 day (8 hours)

4.800 m³ / 3,84 €

1 year (250 days at 8 hours per day)

1.200.000 m³ / 960,00 €

1 year (250 days at 24 hours per day)

3.600.000 m³ / 2.880,00 €

EXPLORIS EcoPlus®

1 hour

600 m³ / 0,48 €

1 day (8 hours)

3.000 m³ / 2,40 €

1 year (250 days at 8 hours per day)

750.000 m³ / 600,00 €

1 year (250 days at 24 hours per day)

2.250.000 m³ / 1.800,00 €

Savings with EXPLORIS EcoPlus®

1 hour

0,18 €

1 day (8 hours)

1,44 €

1 year (250 days at 8 hours per day)

360,00 €

1 year (250 days at 24 hours per day)

1.080,00 €

Dimensions in mm / Volume flow rate in m³/h

Assumption: 1,000m³ of conditioned laboratory air costs €0.80.

Width
1200
1500
1800
2000
2100
Front height2300/25502300/25502300/25502300/25502300/2550
Chamber height2300/26002300/26002300/26002300/26002300/2600
Depth900900900900900
Usable space width11001400170019002000
Usable space height1115/14151115/14151115/14151115/14151115/1415
Usable space depth760760760760760
Work height900900900900900
Minimal permissable volume flow rate*300375450530530
Specified volume flow rate360450540630630
Maximum permissible volume flow rate15001500150015001500
Dimensions in mm / Volume flow rate in m³/h
* Alarm value

Your work is what matters

When selecting a fume cupboard, the most important considerations are the activities you do and substances you use.

Organic solvents
Weak acids
Diluted mineral acids
Cold concentrated mineral acids
Hot concentrated mineral acids
Hydrofluoric acid
Radioactive substances
High thermal load
= Suitable
= Occasional use
= Not suitable

Product data

The ventilation system offers further savings potential: Smaller pipe cross-sections and smaller dimensioned fans can save up to 20 percent on investment costs. Afterwards you will find all information on dimensions, potential savings and volume flow.

Fume cupboard control TouchTronic

Easy operation of fume cupboards

As a control element for a wide range of functions, the new TouchTronic combines fume cupboard control and monitoring with high computing power. The combination of work steps in one unit saves time and also protects everyone else in the lab: warnings can be easily shown on the display. Even when wearing gloves, the IPS touch screen recognises the touch.

Fume cupboard control TouchTronic

Easy operation of fume cupboards

As a control element for a wide range of functions, the new TouchTronic combines fume cupboard control and monitoring with high computing power. The combination of work steps in one unit saves time and also protects everyone else in the lab: warnings can be easily shown on the display. Even when wearing gloves, the IPS touch screen recognises the touch.